Recent Searches
    Series ()
      Models ()
        Keywords

          Programmable ControllerKV-5000/3000 series

          KL-DC1V

          DC Voltage Input Unit

          SPECIFICATIONS

          Select Language

          Model

          KL-DC1V

          General Specifications

          Power voltage

          24 VDC ± 10%, Class 2

          Internal current consumption (excluding current for driving input circuits)

          170mA or less

          Operating ambient temperature

          0 to +50°C (no freezing)

          Ambient temperature for storage

          -20 to +70°C

          Operating ambient humidity

          35 to 85%RH(no condensation)

          Withstand voltage

          1,500 VAC for 1 minute (between the power supply terminal and each terminal and between all the terminals and the case)

          Noise immunity

          1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator), conforms to IEC standards (IEC 61000-4-2/-3/-4/-6)

          Insulation resistance

          100 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and each I/O terminal and between all the terminals and the case)

          Operating environment

          Minimal amount of dust and corrosive gas present

          Pollution degree

          2

          Weight

          approx 350g

          Shock resistance

          Conforms to JIS B 3502 and IEC 61131-2, 147 m/s2, operating time: 11 ms, 3 times in each of the 3 directions

          General specifications

          Measurement type

          DC voltage

          Vibration resistance

          Intermittent vibration

          Frequency: 10 to 57 Hz

          Amplitude: 0.075 mm*1

          Frequency: 57 to 150 Hz

          Acceleration: 9.8 m/s2*1

          Continuous vibration

          Frequency: 10 to 57 Hz

          Amplitude: 0.035 mm*1

          Frequency: 57 to 150 Hz

          Acceleration: 4.9 m/s2*1

          Measurement category

          III

          Wire temperature rating

          +60°C or more

          Performance specifications

          Number of channels

          1CH

          Number of ranges

          3

          Range switching

          Setting: Use the setting switch. Connection: The connection terminal varies depending on the range.

          Input method

          Single-ended

          Sampling rate

          Normal mode: 1 ms (1,000 times/sec.), high-precision mode: 100 ms (10 times/sec.)

          Input range*2

          Range 1: 0 to 10 V, range 2: ±10 V, range 3: ±100 V*2

          Displayable range

          Range 1: 0 to 20 mA

          0.000 to 10.999V*3

          Range 2: ±10 mA

          -10.999 to 10.999V*3

          Range 3: ±100 mA

          -109.99 to 109.99V*3

          Resolution

          Normal

          Range 1: 0 to 20 mA

          1 mV (0.001 V; 1/10000)*4

          Range 2: ±10 mA

          1mV(0.001V)1/20000*2

          Range 3: ±100 mA

          10mV(0.01V)1/20000*2

          High accuracy

          Range 1: 0 to 20 mA

          100 µV (0.1 mV; 1/100000)*2

          Range 2: ±10 mA

          100 µV (0.1 mV; 1/200000)*2

          Range 3: ±100 mA

          1mV(0.001V)1/200000*2

          Input impedance

          Range 1: 0 to 20 mA

          1 MΩ

          Range 2: ±10 mA

          Range 3: ±100 mA

          4 MΩ

          Absolute maximum input current

          Range 1: 0 to 20 mA

          ±100 V

          Range 2: ±10 mA

          Range 3: ±100 mA

          ±150 V

          Measurement accuracy (25 ±5°C)

          Range 1: 0 to 20 mA

          ±0.1% of F.S. ± 1 digit

          Range 2: ±10 mA

          Range 3: ±100 mA

          ±0.2% of F.S. ± 1 digit

          Measurement accuracy (0 to 50°C)

          Range 1: 0 to 20 mA

          ±0.5% of F.S. ± 1 digit

          Range 2: ±10 mA

          Range 3: ±100 mA

          ±0.6% of F.S. ± 1 digit

          Control input

          2 (Parameters are used to switch between the KL input, peak/bottom hold control input, and 0-point adjustment input.)

          Controloutput

          2 transistor (NPN open-collector) outputs (Parameters are used to switch between the KL output and comparator output.)

          Setting data

          Recorded to the EEPROM (rewritable 1,000,000 times)

          Other functions

          Hold (peak and bottom), 0-point adjustment, comparator output, filter setting (LPF and HPF), time average (simple and moving), scaling setting, display unit changing, lock

          Control I/O specifications

          External calibration input signal

          Number of inputs

          2

          Maximum input voltage

          DC26.4V

          Input rated voltage

          DC24V 5.3mA

          Minimum ON voltage

          19V

          Maximum OFF current

          1.5mA

          Common ground

          2/common

          Input time constant

          10ms

          Control output

          Number of outputs

          2

          Output

          Transistor NPN output

          Rated load

          DC30V 0.1A

          Peak load current

          0.2A

          Leakage current (at OFF)

          100 µA or less

          Residual voltage (at ON)

          DC0.8V or less

          Common ground

          2/common

          ON/OFF response time

          Off to on: 10 µs or less (between 5 and 100 mA), on to off: 50 µs or less (between 5 and 100 mA)

          KL link specifications

          Supported master units

          Model: KL-N20V, supported PLC: KEYENCE KV-1000/700; model: KL-N10V, supported PLC: KEYENCE KV-10/16/24/40; model: KV-P16*L (built-in PLC), supported PLC: KEYENCE; model: KL-N20A, supported PLC: Mitsubishi AnA, AnA, AnU, QnA, AnSH, and Q2AS; model: KL-N20C, supported PLC: Omron C200H/HS, SYSMAC α, and CS1 (excluding the C200H-02/22), KEYENCE VT2-12F/10F/10T/10S/8T/8S/7S/5T/5S/5M and DT-100

          Communication address

          00 H to FE H(0 to 254)

          Number of occupied words

          EASY mode: reception (KL to PLC): 5 words, transmission (PLC to KL): 3 words; FULL mode: reception (KL to PLC): 7 words, transmission (PLC to KL): 5 words*5

          Communication speed

          2.5 Mbps, 625 kbps, 156 kbps (set with parameters)*6

          *1 Conforms to JIS B 3502, IEC61131-2
          Number of sweeps: 10 times respectively in the X, Y, and Z directions (80 minutes)
          *2 Select with the setting switch.
          *3 Even if a voltage that exceeds the input range has been input, if it is within the displayable range, it will be displayed (up to 10,999 can be displayed with an absolute value). In this case, display will be performed from the lowest digit; the upper 2 digits will be displayed with A flashing. (Ex: When using 10.500 V input with a range of 2 (input range ±10 V), A.500 is displayed) If a voltage that exceeds the displayable range has been input, FFFF (-FFFF) will be displayed. Also, when scaling is in effect, if the measurement value exceeds the displayable range with an input voltage in the input range, EFFF (-EFFF) will be displayed.
          *4 When scaling is enabled, the maximum resolution is 0.5 mV (1/20000).
          *5 In the direction of transmission/reception when seen from the master unit.
          *6 The <<KL-DC1A/KL-DC1V/KL-LC1>> do not support a communication speed of 5 Mbps.

          • PLC/HMI User Support
          • General Catalogue Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Controls