Recent Searches
    Series ()
      Models ()
        Keywords

          Image Dimension Measurement SystemIM-6000 series

          IM-6700

          Controller

          SPECIFICATIONS

          Select Language

          Model

          IM-6700

          Type

          Controller

          Image sensor

          1" 6.6 mega pixel monochrome CMOS

          Display

          10. 4" LCD monitor (XGA: 1024 × 768)
          External monitor connectable (clone output)

          Receiver lens

          Double telecentric lens

          Image measurement

          Field of view

          Wide field: ø100 × L200 mm, High precision: 25 × L125 mm

          Minimum display unit

          0.1 µm

          Repeatability

          W/o stage movement

          Wide field: ±1 µm, High precision: ±0. 5 µm

          With stage movement

          Wide field: ±2 µm, High precision: ±1. 5 µm

          Measurement accuracy (±2σ)

          W/o binding

          Wide field: ±5 µm*1, High precision: ±2 µm*2

          With binding

          Wide field: ±(7 + 0. 02 L) µm*3, High precision: ±(4 + 0. 02 L) µm*4

          External remote input

          Non-voltage input (with and without contact)

          External output

          OK/NG/FAIL/MEAS.

          Relay output/rated load: 24 VDC, 0. 5 A/ON resistance

          Interface

          LAN

          RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)

          USB 2.0 series A

          6 ports (front: 2, rear: 4)

          Record

          Hard disk drive

          250 GB

          Illumination system

          Transparent

          Telecentric transparent illumination

          Ring

          Four division, multi-angle illumination (electric)
          Slit ring (directivity) illumination (electric)

          X stage

          Moving range

          100 mm (electric)

          Z stage

          30 mm (electric)

          Withstand load

          2 kg

          Measurement points

          99 points max. (99 × 9 points possible when the function for consolidating measurement settings is used)

          Pattern search (profi le tracking function)

          XYθ (with 360° rotary position compensation)

          Pattern registration

          1000 patterns or more*5

          Measurement time

          2 seconds*6

          Basic measurement function

          Distance measurement

          8 types (point-point/line-point/line-line/circle-point/circle-line/circle-circle/circle/arc)

          Angle measurement

          Provided

          Calculation

          Virtual line function

          Point

          Middle point/intersection

          Conjunction edge

          Line conjunction/circular conjunction

          Line

          6 types (midline/perpendicular line/parallel lines/tangent line/line passing through a point/approximate line)

          Circle

          Middle circle/approximate circle/auxiliary circle/inscribed and circumscribed circle

          Application tool

          Pitch measurement

          Line/circumference

          Pitch angle

          Width measurement

          Edge width

          Thickness measurement

          Thickness measurement/gap measurement between inner and outer diameters

          Special tool

          Rounded corner/curved surface/oval/reticle/point position/perimeter/area/screw/automatic measurement

          GD&T

          Shape tolerance

          Straightness/circularity/profile

          Orientation tolerance

          Squareness/parallelism

          Position tolerance

          Point position/concentricity

          Element tool

          Point

          Point (on a line or arc)/maximum and minimum (rectangle, circle, arc)

          Line

          Line/centre line/peak line

          Circle

          Circle/arc/peak circle/peak arc

          Profi le extraction

          Provided

          Special tool

          Automatic generation/gauge line

          Manual measurement

          Provided

          Coordinate system confi guration

          Batch confi guration of tolerance

          Element list editing

          Measurement setting data binding function

          DXF export function

          Automatic measurement function

          Q-DAS data save function

          Measurement settings support functions

          Provided*7

          Power supply

          Power voltage

          100 to 240 VAC 50/60 Hz

          Power consumption

          310 VA max.

          Environmental resistance

          Ambient temperature

          +10 to +35 °C

          Relative humidity

          20 to 80 % RH (No condensation)

          Weight

          Approx. 8 kg

          *1 In the range of ø80 mm from the centre of the stage within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position
          *2 In the range of ø20 mm from the centre of the stage within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position
          *3 In the range of ø80 × 180 mm from the centre of the stage, within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units)
          *4 In the range of ø20 × 120 mm from the centre of the stage, within the operating ambient temperature range of +23°C ±1.0°C at the focused focal point position, and with a load weighing 1 kg or less on the stage (L = amount of stage movement in mm units)
          *5 Depending on the measurement setting data and number of data pieces being stored
          *6 Without pattern search, applied measurement, and stage movement
          *7 Optimum lighting guide, optimum lighting search, automatic edge extraction parameter adjustment function, and multiple edge extraction function

          Measurement Systems Library