Recent Searches
    Series ()
      Models ()
        Keywords

          High-Accuracy Digital Contact SensorGT2 series

          GT2-71MCP

          Amplifier Unit, Analog Output Type PNP

          SPECIFICATIONS

          Select Language

          Model

          GT2-71MCP

          Output

          PNP output

          Mounting type

          DIN-rail mount

          Main unit/Expansion unit

          Main unit

          Power consumption

          Normal

          2,700 mW max. (30 V, 90 mA max.)

          Power saving (Eco)

          2,200 mW max. (30 V, 73.3 mA max.)

          Display power

          Measured value display

          6 + 1/2-digit 7-segment LED (red)

          Other displays

          2-colour, 13-level bar LED display (red, green), indicators (red, green)

          Display range

          -199.999.9 to 199.999.9

          Display resolution

          0.1 μm

          Sampling rate

          1,000 times/sec.

          Control input

          Timing/preset/
          reset/bank input

          No-voltage input

          Control output

          HH/HI/GO/LO/LL

          PNP open collector, 30 V 50 mA or less, residual voltage 1 V or less*1*2

          Analogue output

          4 to 20 mA with a max. load resistance of 350 Ω
          Set response time +1 ms

          Response time

          hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s

          Environmental resistance

          Ambient temperature

          -10 to +50 °C (GT2-71MCN/71MCP: -10 to +45 °C when expansion unit (s) is connected) (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Materials

          Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC

          Weight

          Approx. 70 g

          *1 When adding expansion units, there are the following restrictions according to the number of connected units.
          [When 2 to 8 units are connected including the main unit]
          Power supply voltage: 20 to 30 VDC, Control output current: 20 mA or less, (GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C
          [When 9 to 15 units are connected including the main unit]
          Power supply voltage: 20 to 30 VDC, Control output current: 10 mA or less (including the DL-RB1A output current), Residual voltage: 1.5 V or lower, (GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C
          *2 The GT2-71MCN(P) does not have HH/LL.

          Contact Sensor Tips

          Measurement Sensors