Recent Searches
    Series ()
      Models ()
        Keywords

          Separate Amplifier Type Pressure SensorAP-40 series

          AP-41

          Sensor Head: Negative pressure Type, -101.3 kPa

          SPECIFICATIONS

          Select Language

          Model

          AP-41

          Application

          Gauge pressure

          Type

          Negative pressure

          Rated pressure

          0 to -101.3 kPa

          Fluid type

          Air, non-corrosive gasses

          Temperature characteristics

          ±2 % of F.S. (When the temperature varies from 25 °C)

          Pressure port

          M5 male threaded

          Environmental resistance

          Pressure resistance

          500 kPa

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 4 hours in each of the X, Y, and Z directions

          Shock resistance

          1,000 m/s2, 10 times in each of X, Y and Z directions, total of 60 times

          Material

          Case: PBT, Screw: SUS303, Cable: PVC

          Weight

          Approx. 70 g (including cable)