          SPECIFICATIONS

          Select Language

          Model

          FS-M0

          Type

          0-line expansion unit

          Output

          -

          Light source

          Red LED

          Sensitivity adjustment/Mode selection

          8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

          Response time

          410 µs to 1.2 ms*1

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output: Red LED
          Stable operation: Green LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          Input

          Control output

          Stability output

          Protection circuit

          Reversed polarity protection, Overcurrent protection, Surge absorber

          Unit expansion

          Up to 16 expansion units can be connected (a total of 17 units)*2

          Mutual interference suppression

          FINE : 4, TURBO/SUPER: 8

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*3

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C (No freezing)*4

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Weight

          Approx. 20 g

          *1 The response speed varies depending on the number of expansion units connected.
          *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
          3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
          *3 Power to the FS-T2/T0/M2/M0 is supplied through the FS-T1/M1/V1/V11/R0, PS-T1, LV-21A/11A or CZ-V1.
          *4 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended