CMOS Multi-Function Analogue Laser Sensor

IL series

Catalogues View Catalogue

Sensor heads IL-065

IL-065 - Sensor heads

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • CSA

Specifications

Model

IL-065

Reference distance

65 mm

Measurement range

55 to 105 mm

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*1
Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. 550 x 1,750 µm

Linearity

±0.1% of F.S. (55 mm to 75 mm)*2*3

Repeatability

2 µm*4

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.06% of F.S./°C*3

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 7,500 lux*5

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 75 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50.
*2 Value when measuring the KEYENCE standard target (white diffuse object).
*3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms.
*5 Value when the sampling rate is set to 2 ms or 5 ms.

Data Sheet (PDF) Other Models