Recent Searches
    Series ()
      Models ()
        Keywords

          CMOS Multi-Function Analogue Laser SensorIL series

          IL-065

          Sensor heads

          SPECIFICATIONS

          Select Language

          Model

          IL-065

          Reference distance

          65 mm

          Measurement range

          55 to 105 mm

          Light source

          Type

          Red semiconductor laser, wavelength: 655 nm (visible light)

          Laser class

          Class 2 (FDA (CDRH) Part1040.10)*1
          Class 2 (IEC 60825-1)

          Output

          560 µW

          Spot diameter (at standard distance)

          Approx. 550 x 1,750 µm

          Linearity

          ±0.1% of F.S. (55 mm to 75 mm)*2*3

          Repeatability

          2 µm*4

          Sampling rate

          0.33/1/2/5 ms (4 levels available)

          Operation status indicators

          Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED

          Temperature characteristics

          0.06% of F.S./°C*3

          Environmental resistance

          Enclosure rating

          IP67

          Pollution degree

          3

          Ambient light

          Incandescent lamp: 7,500 lux*5

          Ambient temperature

          -10 to +50 °C (No condensation or freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Material

          Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

          Weight

          Approx. 75 g

          *1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50.
          *2 Value when measuring the KEYENCE standard target (white diffuse object).
          *3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
          *4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms.
          *5 Value when the sampling rate is set to 2 ms or 5 ms.