Recent Searches
    Series ()
      Models ()
        Keywords

          High-speed, High-Accuracy, digital inductive displacement sensors EX-V series

          EX-110V

          Sensor Head

          SPECIFICATIONS

          Select Language

          Model

          EX-110V*1

          Type

          Sensor head

          Amplifier unit

          EX-V02(P)

          Shape

          M10 x 18 mm Threaded

          Measuring range

          0 to 2 mm

          A/D converting system

          Display range

          -19999 to +19999

          Linearity

          ±0.3% of F.S.

          Resolution (No. of averaging
          measurements: 64)

          0.4 µm

          Sampling rate

          40000 samplings max./sec. *2

          Display speed

          20 times/sec.

          Display power

          7-segment 2-colour LED

          Over-range alarm

          ±FFFF is displayed.

          Control output

          NPN open-collector or non-voltage contact signal

          Controloutput

          Setting method

          Upper/lower 2-level setting x 4 patterns (selectable)

          Control output

          Signal

          Controloutput

          Response time

          0.075 ms (at maximum speed)

          OFF-delay time

          60 ms (ON/OFF selectable)

          Strobe output

          NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.)

          Control output

          Alarm output

          Analogue output voltage

          Output voltage

          ±5V

          Impedance

          100 Ω

          Response time

          0.075 ms (at maximum speed)

          Temperature characteristics

          0.07% of F.S./°C *3

          Major functions

          FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.

          Rating

          Power voltage

          24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          240 mA or less

          Environmental resistance

          Ambient temperature

          -10 to +60 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Weight

          Approx. 55 g (including 3-m cable)

          *1 The above data was obtained using an iron target (S45C, SS400, t=1 mm). When measuring aluminium, copper, or stainless steel targets, refer to the linear characteristics for these materials.
          *2 When the digital filter function is used, the sampling rate is 20000 sampling/sec.
          *3 When the distance between the sensor head and the target is within 50% of the measuring range.

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors

          Sensor Library

          • General Catalogue Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Sensors