Recent Searches
    Series ()
      Models ()
        Keywords

          High-speed Clean Air Barrier Static EliminatorSJ-G series

          SJ-G060

          Bar Type Main Unit 600 mm

          [Discontinued model]

          This model has been discontinued.

          Recommended Replaceable Products
          To contact us:

          SPECIFICATIONS

          Select Language

          Model

          SJ-G060*1

          Ion generation method

          Corona discharge method

          Structure

          Shockless resistor connection type

          Voltage application method/Applied voltage

          Pulse AC method/±7,000 V

          Ion balance control method

          I.C.C. method

          Ion balance

          ±30 V*2

          Operating distance

          50 to 2,000 mm

          Control input

          NPN open-collector or no-voltage contact signal

          Control output

          NPN type photo relay, 100 mA max. (40 V max.)

          Major applications

          Alarm output, Ion level alarm output, condition alarm output,
          Ion balance adjustment (remote control),
          RS-485 communication function, connection via crossover wiring,
          C.A.B. structure, L.P.C. function

          Air purge connection port

          M5

          Air purge supplied pressure

          0.2 MPa or less

          Rating

          Power voltage

          24 to 36 VDC ±10 %

          Over-voltage category

          I

          Pollution degree

          2

          Current consumption

          250 mA (at 24 VDC)/150 mA (at 36 VDC)

          Environmental resistance

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Electrode probe

          Tungsten

          Electrode

          Stainless steel

          Main unit

          ABS resin

          Weight

          Controller

          Bar

          Approx 750 g

          *1 A 10-pin I/O cable or a 10-to-10 pin modular cable is required for connection.
          *2 50 mm 33 Hz, 600 mm 10 Hz, 1,500 mm 1 Hz, ambient temperature: 0 to 50ºC, relative humidity: 35 to 65% RH, below down-flow 0.3 m/s.