Recent Searches
    Series ()
      Models ()
        Keywords

          Vision SensorIV series

          IV-H500MA

          Standard, Monochrome, Automatic focus model

          SPECIFICATIONS

          Select Language

          Model

          IV-H500MA

          Type

          Standard distance

          Installed distance

          50 to 500 mm

          View

          Installed distance 50 mm: 25 (H) x 18 (V) mm to
          installed distance 500 mm: 210 (H) x 157 (V) mm

          Image sensor

          Type

          1/3 inch monochrome CMOS

          Pixel

          752 (H) x 480 (V)

          Focus adjustment

          Auto*1

          Exposure time

          1/10 to 1/25,000

          Lights

          Illumination

          Red LED

          Lighting method

          Pulse lighting/DC lighting is switchable

          Tools

          Type

          Shape Detection, Colour Area*2, Area*3, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment (1-Axis/2-Axis Adjustment)

          Number

          Detection tools: 16 tools, position adjustment tool: 1 tool*4

          Switch settings (programs)

          32 programmes

          Image history

          Numbers

          300 images*5*6

          Condition

          NG only/All is selectable*6

          Analysis information

          OFF/Statistics/Histograms/Matching rate list is switchable
          Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools
          Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs
          Matching rate list: Judgment results list by tools, matching rate list by tools, judgment bar list by tools*7

          Other functions

          HDR, HighGain, Colour filters*2, Digital zoom*3, Brightness correction, Tilt correction, White balance*2,
          Mask function, Colour histogram, Test run, ToolAutoTune, Input monitor, Output test,
          Security settings, Simulator*8, Sensor date/time information addition, Scaling function, Failing sensor list, Failure hold

          Indicators

          PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

          Input

          Type

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Inputs

          6 inputs (IN1 to IN6)

          Function

          IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
          Assignable functions: Programme switching, Clear error, External master image registration

          Output

          Type

          Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
          For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower
          For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower

          Outputs

          4 outputs (OUT1 to OUT4)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool,
          Result of the logical operation of each tool, Main unit/expansion unit logical output

          Ethernet

          Standard

          100BASE-TX/10BASE-T*9

          Connector

          M12 4pin connector*9

          Network function

          FTP client, EtherNet/IPTM, PROFINET

          Rating

          Power voltage

          24 VDC ±10 % (including ripple)

          Current consumption

          0.6 A or less

          Environmental resistance

          Enclosure rating

          IP67*10

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*11

          Shock resistance

          500 m/s2, 3 times in each of 6 directions*11

          Material

          Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM

          Weight

          Approx. 270 g

          *1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. Focusing position can be registered by programme.
          *2 Colour type only
          *3 Possible with both the colour type and monochrome type
          *4 Tools can be installed by programmes.
          *5 When using the FTP client function: 210 pictures
          *6 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1).
          *7 This can be displayed on the intelligent monitor (IV-M30) or by software for IV (IV-H1).
          *8 Simulator can be used with the IV software (IV-H1).
          *9 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1).
          *10 Except when polarised filter attachment (OP-87436/OP-87437) is mounted
          *11 Except when IV-G dome attachment (IV-D10) is mounted