Safety Interlock Switches
GS series
Non-contact type Standard type NPN Standard cable 10 m GS-11N10
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | GS-11N10  | |||
Type  | Standard type  | |||
Output type  | NPN  | |||
Operating distance  | Front  | Sao(OFF→ON)  | 10 mm  | |
Sar(ON→OFF)  | 18 mm  | |||
Side  | Sao(OFF→ON)  | 6 mm  | ||
Sar(ON→OFF)  | 14 mm  | |||
Response time  | Detection  | Detect →Not detect  | 20 ms + 2 ms × (number of units cascaded -1) *1  | |
Not detect →Detect  | 30 ms + 25 ms × (number of units cascaded -1) *1  | |||
Door operation  | Acceptable operation frequency  | 3 Hz  | ||
Cascading  | Standard  | Max. 30 units  | ||
Using Y-shaped connector  | —  | |||
Control output (OSSD output)  | Output  | Transistor outputs × 2  | ||
Max. load current  | Max. 100 mA  | |||
Residual voltage (during ON)  | Max 2.5 V (with a cable length of 5 m)  | |||
OFF state voltage  | Max 2.0 V (with a cable length of 5 m)  | |||
Leakage current  | Max. 500 µA  | |||
Max. capacitive load  | 2.2 µF  | |||
Load wiring resistance  | Max. 2.5Ω  | |||
AUX (Non-safety related output)  | Output  | Transistor output  | ||
Number of outputs  | 1  | |||
Max. load current  | 50 mA  | |||
Residual voltage (during ON)  | Max 2.5 V (with a cable length of 5 m)  | |||
External input (Short-circuit current)  | Safety input  | Approx. 1.5 mA × 2  | ||
Reset/EDM input  | —  | |||
Applicable Standards (Safety)  | EN 61508, IEC 61508 (SIL3)  | |||
Protection circuit  | Reverse current protection, short-circuit protection and surge protection for each output  | |||
Power supply  | Power voltage  | 24 V DC ±20 % (Ripple P-P 10 % or less, Class2)  | ||
Current consumption  | 0.8 W  | |||
Environmental resistance  | Enclosure rating  | IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)  | ||
Operating ambient temperature  | -20°C to +55°C (No freezing)  | |||
Operating relative humidity  | 5% to 95% RH  | |||
Storage temperature  | -25°C to +70°C (No freezing) *2  | |||
Storage relative humidity  | 5% to 95% RH  | |||
Vibration resistance  | 10 to 55 Hz, Double amplitude 3.0 mm, 5 minutes in each of the X, Y and Z directions (IEC 60947-5-3)  | |||
Shock resistance  | 30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)  | |||
Material  | Sensor main unit  | Case  | Zinc die cast (Nickel chrome plating), PBT, PAR  | |
Cable  | PVC  | |||
Actuator  | Case  | SUS430, SUS304, PBT  | ||
Weight  | Approx. 480 g  | |||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).  | ||||