Specifications
| Model | FU-18*1 | |||
| Optical axis diameter | ø2.5 mm | |||
| Beam emitting direction | Side | |||
| Aperture angle | Approx 2° | |||
| Fibre unit length | 2 m free-cut | |||
| Fibre unit diameter | ø1.0 | |||
| Minimum bend radius | R10 mm | |||
| Minimum detectable object | Object with a diameter of 0.1 mm*2 | |||
| Environmental resistance | Ambient temperature | -40 to +70 °C | ||
| Weight | Approx. 8 g | |||