Digital CMOS Laser Sensor
LR-X series
Standard Model, M8 Connector Type, 50mm range LR-X50C
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | LR-X50C  | |||
Type  | M8 Connector Type*1  | |||
Detecting Distance  | 25.0 to 50.0 mm  | |||
Standard Detectable Deviation  | 0.5 mm  | |||
Display Resolution  | 0.1 mm  | |||
Spot Size  | Approx. 0.2 mm × Approx. 1.5 mm  | |||
Response Time  | 500 μs*2/1 ms/3 ms/10 ms/200 ms Selectable  | |||
Light Source  | Type  | Green laser (505 nm)  | ||
Laser Class  | Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3)  | |||
IO-Link  | Specification v1.1/COM2 (38.4 kbps)  | |||
Function  | Timer Function  | Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot  | ||
Input/Output  | Control Output  | NPN open collector/PNP open collector, N.O./N.C.  *4  | ||
External Input  | External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable  *4  | |||
Protection Circuit  | Protection against reverse power connection, protection against output overcurrent,  | |||
Power supply  | Power voltage  | 16 to 30 VDC (including 10% ripple (P-P) or less), class 2  | ||
Power consumption  | During normal operation: 970 mW (38 mA or less at 24 V, 53 mA or less at 16 V) (Excluding Load Current)  | |||
Environmental resistance  | Enclosure rating  | IP65/IP67(IEC60529)  | ||
Ambient light  | Incandescent lamp: 16,000 lx or less  | |||
Ambient temperature  | -10°C to +50°C (no freezing)  | |||
Relative humidity  | 35 to 85% RH (no condensation)  | |||
Vibration resistance  | 10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes  | |||
Shock resistance  | 1,000 m/s2 (100G) 6 times each for X, Y, and Z axes  | |||
Material  | Head Case: SUS316L; Head Lens Cover: PSU  | |||
Accessories  | Instruction manual, laser warning label  | |||
Weight  | Approx. 35 g  | |||
*1 Ensure the cable length is 30 m or less for the M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.  | ||||