Inductive Gauging Sensor
AS series
Specs Inductive Gauging Sensor AS series
Controller
|
Model |
AS-440-01U |
AS-440-02U |
AS-440-05U |
AS-440-10U |
|||
|
Image |
|
|
|
|
|||
|
Type |
General-use amplifier unit |
||||||
|
Sensor head |
AH-305 |
AH-110 |
AH-416 |
AH-422 |
|||
|
Shape |
Cylindrical, diameter: 5.4 |
M10 threaded |
Cylindrical and threaded, diameter: 14.5 |
Cylindrical and threaded, diameter: 22 |
|||
|
Measuring range |
0 to 1mm |
0 to 2mm |
0 to 5mm |
0 to 10mm |
|||
|
Analogue output voltage |
Output voltage |
0 to 1V |
0 to 2V |
0 to 5V |
0 to 10V |
||
|
Impedance |
100 Ω |
||||||
|
Resolution |
0.1% of F.S. |
||||||
|
Linearity |
±1% of F.S. |
||||||
|
Response |
3.3 kHz (-3 dB) |
||||||
|
Temperature |
Sensor head |
0.03% of F.S./°C*1 |
|||||
|
Temperature characteristics |
Amplifier unit |
0.05% of F.S./°C*1 |
|||||
|
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
|||||
|
Power consumption |
5VA |
||||||
|
Environmentalresistance |
Enclosure rating |
Sensor head |
IP67 |
||||
|
Operating ambient temperature |
Sensor head |
-10 to +60°C, No condensation |
|||||
|
Amplifier unit |
0 to +50°C |
||||||
|
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
|||||
|
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
||||||
|
Weight |
Sensor head |
Approx 45 g |
Approx 55g |
Approx 75 g |
Approx 200g |
||
|
Weight (including cord) |
Amplifier unit |
Approx 320g |
|||||
|
*1 When the distance between the sensor head and the target is within 50% of the measurement range. |
|||||||