Fully Operational with Expanded Resources Click for the latest on how KEYENCE is continuing to support our customers with quick delivery, off-site testing, virtual demos and more.
  1. Home
  2. Products
  3. Sensors
  4. Inductive Proximity Sensors
  5. Separate Amplifier Proximity Sensor
  6. Specs

Separate Amplifier Proximity Sensor

ES series

Select Language

Model

EH-302

EH-303A

EH-305

EH-308

EH-110

EH-114

Type

Standard, Shielded , Cylindrical

Standard, Shielded ,Threaded

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target (iron, t=1 mm)

5 x 5 mm

10 x 10 mm

15 x 15 mm

Stable detecting range

0 to 0.6 mm

0 to 0.8 mm

0 to 1 mm

0 to 2 mm

0 to 5 mm

Maximum detecting distance

1.2 mm

2 mm

3 mm

5 mm

8 mm

Hysteresis

0.04 mm

0.05 mm

0.04 mm

0.05 mm

Repeatability

0.002 mm

0.005 mm

Temperature characteristics

±10% max. of detecting distance at +23°C, within -10 to +60°C

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 29 g (including nuts and 3-m cable)

Approx. 38 g (including nuts and 3-m cable)

Approx. 45 g (including nuts and 3-m cable)

Approx. 47 g (including nuts and 3-m cable)

Approx. 55 g (including nuts and 3-m cable)

Approx. 62 g (including nuts and 3-m cable)

Model

EH-605

EH-614A

EH-108

EH-910

Type

Standard , Shielded , ULTRA thin

Oil-resistant, Shielded, Threaded*1

Solvent resistant , Shielded , Cylindrical

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target (iron, t=1 mm)

5 x 5 mm

15 x 15 mm

10 x 10 mm

Stable detecting range

0 to 1 mm

0 to 5 mm

0 to 1.5 mm

0 to 2 mm

Maximum detecting distance

3 mm

8 mm

2.5 mm

4.5 mm

Hysteresis

0.05 mm

0.07 mm

0.06 mm

Repeatability

0.002 mm

0.005 mm

Temperature characteristics

-10 to+20% max. of detecting distance at 23°C, within -10 to +60°C

±10% max. of detecting distance at +23°C, within -10 to +60°C

-10 to+15% max. of detecting distance at 23°C, within 0 to 60°C

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 30 g (including nuts and 3-m cable)

Approx. 57 g (including nuts and 3-m cable)

Approx. 51 g (including nuts and 3-m cable)

Approx. 53 g (including nuts and 3-m cable)

*1 Not designed for immersed use.

Model

EH-305S

EH-308S

EH-110S

Type

with stainless steel spiral tube, Shielded , Cylindrical

with stainless steel spiral tube , Shielded , Threaded

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target (iron, t=1 mm)

5 x 5 mm

10 x 10 mm

Stable detecting range

0 to 1 mm

0 to 2 mm

Maximum detecting distance

3 mm

5 mm

Hysteresis

0.05 mm

0.04 mm

Repeatability

0.002 mm

0.005 mm

Temperature characteristics

±10% max. of detecting distance at +23°C, within -10 to +60°C

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 76 g (including nuts and 3-m cable)

Approx. 88 g (including nuts and 3-m cable)

Approx. 100 g (including nuts and 3-m cable)

Model

EH-402

EH-416

EH-422

EH-430

EH-440

EH-290

Type

Standard , Non-shielded , Cylindrical

Standard , Non-shielded , Cylindrical and threaded

Standard , Non-shielded , Cylindrical

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target (iron, t=1 mm)

10 x 10 mm

20 x 20 mm

25 x 25 mm

30 x 30 mm

40 x 40 mm

150 x 150 mm

Stable detecting range

0 to 3 mm

0 to 6 mm

0 to 9 mm

0 to 12 mm

0 to 18 mm

0 to 35 mm

Maximum detecting distance

7 mm

13 mm

18 mm

25 mm

36 mm

70 mm

Hysteresis

0.04 mm

0.05 mm

0.06 mm

0.08 mm

0.1 mm

0.2 mm

Repeatability

0.002 mm

0.012 mm

0.02 mm

0.025 mm

0.037 mm

0.075 mm

Temperature characteristics

+30%, -10% max. of detecting distance at +23°C, within -10 to +60°C

±10% max. of detecting distance at +23°C, within -10 to +60°C

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 28 g (including nuts and 3-m cable)

Approx. 72 g (including nuts and 3-m cable)

Approx. 175 g (including nuts and 3-m cable)

Approx. 225 g (including nuts and 3-m cable)

Approx. 280 g (including nuts and 3-m cable)

Approx. 650 g (including nuts and 3-m cable)

Model

ES-M1*1

ES-M2*1

ES-M1P*1

ES-M2P*1

Type

One-line expansion system

Shape

Main unit

Expansionunit

Main unit

Expansionunit

Operation mode

N.O./N.C. (switch-selectable)

Timer function

10-ms delay / timer OFF switchable*2

Output

NPN

PNP

Output

Control output

NPN open collector 100 mA max.
40 V, residual voltage 1 V max.

PNP open collector 100 mA max.
26.4 V, residual voltage 1 V max.

Disconnection alarm output

NPN open
collector 100 mA max.
40 V,
residual voltage 1 V or less*3

*3

PNP open
collector 100 mA max.
26.4 V,
residual voltage 1 V or less*3

*3

Response time

1 ms max.

Temperature characteristics

Within ±8% of detecting distance at 23°C
when within 0 to 50°C temperature range

Sensitivity adjustment

25-turn trimmer

Protection circuit

Reverse power connection protection, output
overcurrent protection, output surge protection

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less

Current/power consumption

25 mA max.

Environmental resistance

Ambient temperature

0 to +50 °C*4

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 65 g (including nuts and 2-m cable)

Approx. 35 g (including nuts and 2-m cable)

Approx. 65 g (including nuts and 2-m cable)

Approx. 35 g (including nuts and 2-m cable)

*1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290.
*2 During N.O. operating configuration, the off delay timer is 10 ms. During N.C., the on delay timer is 10 ms.
*3 Broken connection warning output is not available on the ES-M2(P).
*4 The ambient temperature changes according to the fo llowing conditions when expansion units are added. When adding units, always attach them to a DIN rail (metal plate) and set the output current to 20 mA or less.
1 to 10 expansion units: 0 to +50 °C
11 to 16 expansion units: 0 to +45 °C

Model

ES-32DC

ES-X38

Type

DC

Operation mode

N.O./N.C. (switch-selectable)

Indicator

Output: Red LED

Output

Control output

NPN: 200 mA (40 V) max.
Residual voltage:
1 V max.

NPN: 100 mA (40 V) max.
Residual voltage:
1 V max.

Disconnection alarm output

NPN: 100 mA (40 V) max.
Residual voltage: 1 V max.

Leakage current (OFF time)

Response time

1 ms max.

Temperature characteristics

±8% of detecting distance at 23°C within 0 to 50°C

Sensitivity adjustment

15-turn trimmer

Rating

Power voltage

10 to 28 VDC, Ripple (P-P) 10 % or less

12 to 24 VDC, Ripple (P-P) 10 % or less

Current/power consumption

18 mA max.

25 mA max.

Environmental resistance

Ambient temperature

0 to +50 °C

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 48 g

Approx. 67 g (including 2-m cable)

  • General Catalogue Request
  • Trade Shows and Exhibitions
  • eNews Subscribe