Ultra High-speed Clean Air Barrier Static Eliminator
SJ-GL series
Recommended Replaceable Products: Energy-Saving High-Speed Sensing Ionizer - SJ-E series
Contact Us: 1-800-88-1358 Enquiry form
Bar Type Main Unit 1320 mm SJ-GL132
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | SJ-GL132  | |||
Ion generation method  | Corona discharge method  | |||
Structure  | Shock-proof resistance coupled  | |||
Voltage application method / Applied voltage  | Pulse AC method / ±6000 V  | |||
Ion balance control method  | I.C.C. method  | |||
Ion balance  | ±30 V *1  | |||
Operating distance  | 50 to 2000 mm  | |||
Control input  | NPN open-collector or non-voltage contact signal  | |||
Control output  | NPN type photorelay, 100 mA max. (40 V max.)  | |||
Major functions  | Alarm output, Ion level alert output, Condition alert output, Electrostatic charge monitor  | |||
Air purge connection port  | Rc1/8  | |||
Air purge supplied pressure  | 0.5 MPa max. *2  | |||
Static elimination barlength  | 1354 mm*3  | |||
Effective length  | 1320 mm*4  | |||
Rating  | Power voltage  | 24 to 36 VDC ±10 %  | ||
Overvoltage category  | I  | |||
Pollution degree  | 2  | |||
Current consumption  | 450 mA  | |||
Environmental resistance  | Ambient temperature  | 0 to +40 °C  | ||
Relative humidity  | 35 to 85 % RH (No condensation)  | |||
Material  | Electrode probe  | Tungsten  | ||
Ground electrode  | Stainless steel  | |||
Body  | ABS  | |||
Weight  | Static elimination bar  | Approx 1800 g  | ||
*1 Measured value under the following conditions: Operating distance: 300 mm (33 Hz), 600 mm (10 Hz) and 1500 mm (1 Hz) Operating ambient temperature: 0 to +40°C  | ||||