Radar Level Sensor
FR series
Short range amplifier unit with separate display M8 Connector Type Main Unit FR-SA1C
 
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
| Model | FR-SA1C | |||
| Type | Short Separated Amplifier Unit M8 connector Main Unit | |||
| Response time | 0.4 s, 1.5 s, 4 s (default value), 10 s | |||
| Output | No. of control outputs | Maximum 2 | ||
| Control output/auxiliary output | NPN/PNP open collector (switchable) | |||
| Analogue output | 0–20 mA/4–20 mA | |||
| External input | Short circuit current: 1.5 mA or less Input time: 500 ms or more | |||
| External communication | IO-Link v1.1/COM2 | |||
| Analogue output Precision | Resolution | 1 mm *1 | ||
| Zero accuracy | ±0.1 mA (zero point = 4 mA) *1 | |||
| Full-scale accuracy | ±0.2 mA (full-scale = 20 mA) *1 | |||
| Expansion | — | |||
| Power supply | Power voltage | 24 VDC +25%/−20%*2*3 including ripple, Class2 or LPS | ||
| Power consumption | 1880 mW or less (63 mA or less at 24 V) (Excluding Load Current) | |||
| Environmental resistance | Ambient temperature | –20°C to +55°C (no freezing) *4 | ||
| Relative humidity | Up to 85% RH (no condensation) | |||
| Protection circuit | Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges | |||
| Material | PC | |||
| Weight | Approx. 20 g | |||
| *1 This is the guaranteed value from verification performed at KEYENCE inspection facilities with a load resistance of 250 Ω. Measurement errors may occur depending on the customer’s environment. | ||||
 