Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          Fully Operational with Expanded Resources
          Click for the latest on how KEYENCE is continuing to support our customers with quick delivery, off-site testing, virtual demos and more.
          1. Home
          2. Products
          3. Sensors
          4. Inductive Proximity Sensors
          5. High-speed, High-Accuracy, digital inductive displacement sensors
          6. Specs

          High-speed, High-Accuracy, digital inductive displacement sensors

          EX-V series

          Select Language

          Sensor head

          Model

          EX-305V*1

          EX-110V*1

          EX-416V*1

          EX-422V*1

          EX-614V*1

          Type

          Sensor head

          Amplifier unit

          EX-V01(P)

          EX-V02(P)

          EX-V05(P)

          EX-V10(P)

          EX-V64(P)

          Shape

          ø5.4 x 18 mm Cylindrical

          M10 x 18 mm Threaded

          ø14.5 x 20 mm Cylindrical,threaded

          ø22 x 35 mm Cylindrical,threaded

          14 x 30 x 4.8 mm Thin profile

          Measuring range

          0 to 1 mm

          0 to 2 mm

          0 to 5 mm

          0 to 10 mm

          0 to 4 mm

          Display range

          -19999 to +19999

          Linearity

          ±0.3% of F.S.

          Resolution (No. of averaging
          measurements: 64)

          0.4 µm

          1 µm

          2 µm

          1 µm

          Sampling rate

          40000 samplings max./sec. *2

          Display speed

          20 times/sec.

          Display power

          7-segment 2-colour LED

          Over-range alarm

          ±FFFF is displayed.

          Control input

          NPN open-collector or non-voltage contact (Timing input, Reset input, Auto-zero input, Comparator output disable input, Synchronous input, External setting input)/PNP: Applied voltage; 10 to 30 V

          Controloutput

          Setting method

          Upper/lower 2-level setting x 4 patterns (selectable)

          Control output

          Signal

          NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.)
          PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.)

          Controloutput

          Response time

          0.075 ms (at maximum speed)

          OFF-delay time

          60 ms

          Strobe output

          NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.)

          Alarm output

          NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.)

          Analogue output voltage

          Output voltage

          ±5V

          Impedance

          100 Ω

          Response time

          0.075 ms (at maximum speed)

          Temperature characteristics

          0.07% of F.S./°C *3

          Major functions

          FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.

          Rating

          Power voltage

          24 VDC ±10%, Ripple (P-P): 10% max.

          Current consumption

          240 mA max.

          Environmental resistance

          Ambient temperature

          -10 to +60°C, No freezing

          Relative humidity

          35 to 85%, No condensation

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Weight

          Approx. 45 g (including 3 m cable)

          Approx. 55 g (including 3 m cable)

          Approx. 75 g (including 3 m cable)

          Approx. 200 g (including 3 m cable)

          Approx. 60 g (including 3 m cable)

          *1 The above data was obtained using an iron target (S45C, SS400, t=1 mm). When measuring aluminium, copper, or stainless steel targets, refer to the linear characteristics for these materials.
          *2 When the digital filter function is used, the sampling rate is 20,000 sampling/sec.
          *3 When the distance between the sensor head and the target is within 50% of the measuring range.

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors

          Sensor Library

          • General Catalogue Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE (MALAYSIA) SDN BHD Lot No. B-25-2, Level 25, The Ascent Paradigm,
          No.1, Jalan SS 7/26A, Kelana Jaya
          47301 Petaling Jaya, Selangor, Malaysia
          Phone: 1-800-88-1358
          E-mail: info@keyence.com.my
          Career Opportunities: KEYENCE Career Site

          Sensors