Energy-Saving High-Speed Sensing Ionizer
SJ-E series
Specs Energy-Saving High-Speed Sensing Ionizer SJ-E series
Small flow model
| 
         Model  | 
        
         SJ-E036L  | 
        
         SJ-E060L  | 
        
         SJ-E084L  | 
        
         SJ-E108L  | 
        
         SJ-E132L  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    |||||||
| 
         Structure  | 
        
         Shockless resistive coupling type  | 
    |||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8000 V  | 
    |||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    |||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    |||||||
| 
         Operating distance  | 
        
         50 to 2000 mm  | 
    |||||||
| 
         Control input  | 
        
         Static elimination stop input  | 
        
         NPN open collector or contact point signal without voltage  | 
    ||||||
| 
         Control output  | 
        
         Ion level alarm  | 
        
         NPN open collector, Maximum 100 mA (40 VDC or less)  | 
    ||||||
| 
         Condition alarm  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Communication feature  | 
        
         Remote control communication  | 
    |||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, alarm output  | 
    |||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    |||||||
| 
         Air supply pressure  | 
        
         0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa)  | 
    |||||||
| 
         Effective length  | 
        
         440 mm *3  | 
        
         680 mm *3  | 
        
         920 mm *3  | 
        
         1160 mm *3  | 
        
         1400 mm *3  | 
    |||
| 
         Total length  | 
        
         350 mm  | 
        
         560 mm  | 
        
         800 mm  | 
        
         1040 mm  | 
        
         1280 mm  | 
    |||
| 
         No. of electrodes  | 
        
         5  | 
        
         9  | 
        
         13  | 
        
         17  | 
        
         21  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC to 36 VDC ±10%  | 
    ||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V), 500 mA (at 36 V)  | 
    |||||||
| 
         Overvoltage category  | 
        
         I  | 
    |||||||
| 
         Pollution degree  | 
        
         2  | 
    |||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    ||||||
| 
         Relative humidity  | 
        
         35 to 85% RH (no condensation)  | 
    |||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    ||||||
| 
         Body  | 
        
         ABS/PBT/PP/LCP/PPS/SPS/SUS  | 
    |||||||
| 
         Weight  | 
        
         670 g  | 
        
         850 g  | 
        
         1070 g  | 
        
         1270 g  | 
        
         1500 g  | 
    |||
| 
         *1 Measured under the following conditions.  | 
    ||||||||
Small flow model
| 
         Model  | 
        
         SJ-E156L  | 
        
         SJ-E180L  | 
        
         SJ-E204L  | 
        
         SJ-E228L  | 
        
         SJ-E252L  | 
        
         SJ-E300L  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    ||||||||
| 
         Structure  | 
        
         Shockless resistive coupling type  | 
    ||||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8000 V  | 
    ||||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    ||||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    ||||||||
| 
         Operating distance  | 
        
         50 to 2000 mm  | 
    ||||||||
| 
         Control input  | 
        
         Static elimination stop input  | 
        
         NPN open collector or contact point signal without voltage  | 
    |||||||
| 
         Control output  | 
        
         Ion level alarm  | 
        
         NPN open collector, Maximum 100 mA (40 VDC or less)  | 
    |||||||
| 
         Condition alarm  | 
    |||||||||
| 
         Alarm output  | 
    |||||||||
| 
         Communication feature  | 
        
         Remote control communication  | 
    ||||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, alarm output  | 
    ||||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    ||||||||
| 
         Air supply pressure  | 
        
         0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa)  | 
    ||||||||
| 
         Effective length  | 
        
         1640 mm *3  | 
        
         1880 mm *3  | 
        
         2120 mm *3  | 
        
         2360 mm *3  | 
        
         2600 mm *3  | 
        
         3080 mm *3  | 
    |||
| 
         Total length  | 
        
         1520 mm  | 
        
         1760 mm  | 
        
         2000 mm  | 
        
         2240 mm  | 
        
         2480 mm  | 
        
         2960 mm  | 
    |||
| 
         No. of electrodes  | 
        
         25  | 
        
         29  | 
        
         33  | 
        
         37  | 
        
         41  | 
        
         49  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC to 36 VDC ±10%  | 
    |||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V), 500 mA (at 36 V)  | 
    ||||||||
| 
         Overvoltage category  | 
        
         I  | 
    ||||||||
| 
         Pollution degree  | 
        
         2  | 
    ||||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    |||||||
| 
         Relative humidity  | 
        
         35 to 85% RH (no condensation)  | 
    ||||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    |||||||
| 
         Body  | 
        
         ABS/PBT/PP/LCP/PPS/SPS/SUS  | 
    ||||||||
| 
         Weight  | 
        
         1700 g  | 
        
         1900 g  | 
        
         2100 g  | 
        
         2300 g  | 
        
         2500 g  | 
        
         2900 g  | 
    |||
| 
         *1 Measured under the following conditions.  | 
    |||||||||
High-end model
| 
         Model  | 
        
         SJ-E036H  | 
        
         SJ-E060H  | 
        
         SJ-E084H  | 
        
         SJ-E108H  | 
        
         SJ-E132H  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    |||||||
| 
         Structure  | 
        
         Shockless resistive coupling type  | 
    |||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8000 V  | 
    |||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    |||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    |||||||
| 
         Operating distance  | 
        
         50 to 2000 mm  | 
    |||||||
| 
         Control input  | 
        
         Static elimination stop input  | 
        
         NPN open collector or contact point signal without voltage  | 
    ||||||
| 
         Control output  | 
        
         Ion level alarm  | 
        
         NPN open collector, Maximum 100 mA (40 VDC or less)  | 
    ||||||
| 
         Condition alarm  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Communication feature  | 
        
         Remote control communication  | 
    |||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, alarm output  | 
    |||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    |||||||
| 
         Air supply pressure  | 
        
         0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa)  | 
    |||||||
| 
         Effective length  | 
        
         420 mm *3  | 
        
         660 mm *3  | 
        
         900 mm *3  | 
        
         1140 mm *3  | 
        
         1380 mm *3  | 
    |||
| 
         Total length  | 
        
         350 mm  | 
        
         560 mm  | 
        
         800 mm  | 
        
         1040 mm  | 
        
         1280 mm  | 
    |||
| 
         No. of electrodes  | 
        
         9  | 
        
         17  | 
        
         25  | 
        
         33  | 
        
         41  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC to 36 VDC ±10%  | 
    ||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V), 500 mA (at 36 V)  | 
    |||||||
| 
         Overvoltage category  | 
        
         I  | 
    |||||||
| 
         Pollution degree  | 
        
         2  | 
    |||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    ||||||
| 
         Relative humidity  | 
        
         35 to 85% RH (no condensation)  | 
    |||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    ||||||
| 
         Body  | 
        
         ABS/PBT/PP/LCP/PPS/SPS/SUS  | 
    |||||||
| 
         Weight  | 
        
         680 g  | 
        
         870 g  | 
        
         1100 g  | 
        
         1300 g  | 
        
         1550 g  | 
    |||
| 
         *1 Measured under the following conditions.  | 
    ||||||||
High-end model
| 
         Model  | 
        
         SJ-E156H  | 
        
         SJ-E180H  | 
        
         SJ-E204H  | 
        
         SJ-E228H  | 
        
         SJ-E252H  | 
        
         SJ-E300H  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    ||||||||
| 
         Structure  | 
        
         Shockless resistive coupling type  | 
    ||||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8000 V  | 
    ||||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    ||||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    ||||||||
| 
         Operating distance  | 
        
         50 to 2000 mm  | 
    ||||||||
| 
         Control input  | 
        
         Static elimination stop input  | 
        
         NPN open collector or contact point signal without voltage  | 
    |||||||
| 
         Control output  | 
        
         Ion level alarm  | 
        
         NPN open collector, Maximum 100 mA (40 VDC or less)  | 
    |||||||
| 
         Condition alarm  | 
    |||||||||
| 
         Alarm output  | 
    |||||||||
| 
         Communication feature  | 
        
         Remote control communication  | 
    ||||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, alarm output  | 
    ||||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    ||||||||
| 
         Air supply pressure  | 
        
         0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa)  | 
    ||||||||
| 
         Effective length  | 
        
         1620 mm *3  | 
        
         1860 mm *3  | 
        
         2100 mm *3  | 
        
         2340 mm *3  | 
        
         2580 mm *3  | 
        
         3060 mm *3  | 
    |||
| 
         Total length  | 
        
         1520 mm  | 
        
         1760 mm  | 
        
         2000 mm  | 
        
         2240 mm  | 
        
         2480 mm  | 
        
         2960 mm  | 
    |||
| 
         No. of electrodes  | 
        
         49  | 
        
         57  | 
        
         65  | 
        
         73  | 
        
         81  | 
        
         97  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC to 36 VDC ±10%  | 
    |||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V), 500 mA (at 36 V)  | 
    ||||||||
| 
         Overvoltage category  | 
        
         I  | 
    ||||||||
| 
         Pollution degree  | 
        
         2  | 
    ||||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    |||||||
| 
         Relative humidity  | 
        
         35 to 85% RH (no condensation)  | 
    ||||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    |||||||
| 
         Body  | 
        
         ABS/PBT/PP/LCP/PPS/SPS/SUS  | 
    ||||||||
| 
         Weight  | 
        
         1750 g  | 
        
         1950 g  | 
        
         2150 g  | 
        
         2350 g  | 
        
         2600 g  | 
        
         3000 g  | 
    |||
| 
         *1 Measured under the following conditions.  | 
    |||||||||
Standard model
| 
         Model  | 
        
         SJ-E036A  | 
        
         SJ-E060A  | 
        
         SJ-E084A  | 
        
         SJ-E108A  | 
        
         SJ-E132A  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    |||||||
| 
         Structure  | 
        
         Shockless resistive coupling type  | 
    |||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8000 V  | 
    |||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    |||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    |||||||
| 
         Operating distance  | 
        
         50 to 2000 mm  | 
    |||||||
| 
         Control input  | 
        
         Static elimination stop input  | 
        
         NPN open collector or contact point signal without voltage  | 
    ||||||
| 
         Control output  | 
        
         Ion level alarm  | 
        
         NPN open collector, Maximum 100 mA (40 VDC or less)  | 
    ||||||
| 
         Condition alarm  | 
    ||||||||
| 
         Alarm output  | 
    ||||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, alarm output  | 
    |||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    |||||||
| 
         Air supply pressure  | 
        
         0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa)  | 
    |||||||
| 
         Effective length  | 
        
         420 mm *3  | 
        
         660 mm *3  | 
        
         900 mm *3  | 
        
         1140 mm *3  | 
        
         1380 mm *3  | 
    |||
| 
         Total length  | 
        
         350 mm  | 
        
         560 mm  | 
        
         800 mm  | 
        
         1040 mm  | 
        
         1280 mm  | 
    |||
| 
         No. of electrodes  | 
        
         5  | 
        
         9  | 
        
         13  | 
        
         17  | 
        
         21  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC to 36 VDC ±10%  | 
    ||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V), 500 mA (at 36 V)  | 
    |||||||
| 
         Overvoltage category  | 
        
         I  | 
    |||||||
| 
         Pollution degree  | 
        
         2  | 
    |||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    ||||||
| 
         Relative humidity  | 
        
         35 to 85% RH (no condensation)  | 
    |||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    ||||||
| 
         Body  | 
        
         ABS/PBT/PP/LCP/PPS/SPS/SUS  | 
    |||||||
| 
         Weight  | 
        
         670 g  | 
        
         850 g  | 
        
         1070 g  | 
        
         1270 g  | 
        
         1500 g  | 
    |||
| 
         *1 Measured under the following conditions.  | 
    ||||||||
Standard model
| 
         Model  | 
        
         SJ-E156A  | 
        
         SJ-E180A  | 
        
         SJ-E204A  | 
        
         SJ-E228A  | 
        
         SJ-E252A  | 
        
         SJ-E300A  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    ||||||||
| 
         Structure  | 
        
         Shockless resistive coupling type  | 
    ||||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8000 V  | 
    ||||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    ||||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    ||||||||
| 
         Operating distance  | 
        
         50 to 2000 mm  | 
    ||||||||
| 
         Control input  | 
        
         Static elimination stop input  | 
        
         NPN open collector or contact point signal without voltage  | 
    |||||||
| 
         Control output  | 
        
         Ion level alarm  | 
        
         NPN open collector, Maximum 100 mA (40 VDC or less)  | 
    |||||||
| 
         Condition alarm  | 
    |||||||||
| 
         Alarm output  | 
    |||||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, alarm output  | 
    ||||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    ||||||||
| 
         Air supply pressure  | 
        
         0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa)  | 
    ||||||||
| 
         Effective length  | 
        
         1620 mm *3  | 
        
         1860 mm *3  | 
        
         2100 mm *3  | 
        
         2340 mm *3  | 
        
         2580 mm *3  | 
        
         3060 mm *3  | 
    |||
| 
         Total length  | 
        
         1520 mm  | 
        
         1760 mm  | 
        
         2000 mm  | 
        
         2240 mm  | 
        
         2480 mm  | 
        
         2960 mm  | 
    |||
| 
         No. of electrodes  | 
        
         25  | 
        
         29  | 
        
         33  | 
        
         37  | 
        
         41  | 
        
         49  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC to 36 VDC ±10%  | 
    |||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V), 500 mA (at 36 V)  | 
    ||||||||
| 
         Overvoltage category  | 
        
         I  | 
    ||||||||
| 
         Pollution degree  | 
        
         2  | 
    ||||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    |||||||
| 
         Relative humidity  | 
        
         35 to 85% RH (no condensation)  | 
    ||||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    |||||||
| 
         Body  | 
        
         ABS/PBT/PP/LCP/PPS/SPS/SUS  | 
    ||||||||
| 
         Weight  | 
        
         1700 g  | 
        
         1900 g  | 
        
         2100 g  | 
        
         2300 g  | 
        
         2500 g  | 
        
         2900 g  | 
    |||
| 
         *1 Measured under the following conditions.  | 
    |||||||||
Network model
| 
         Model  | 
        
         SJ-E036N  | 
        
         SJ-E060N  | 
        
         SJ-E084N  | 
        
         SJ-E108N  | 
        
         SJ-E132N  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    |||||||
| 
         Structure  | 
        
         Shockless resistor connection type  | 
    |||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8,000 V  | 
    |||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    |||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    |||||||
| 
         Operating distance  | 
        
         50 to 2,000 mm  | 
    |||||||
| 
         Communication feature  | 
        
         RS-485 communication/remote control communication  | 
    |||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, and alarm output  | 
    |||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    |||||||
| 
         Air supply pressure  | 
        
         0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa) *2  | 
    |||||||
| 
         Effective length  | 
        
         440 mm *3  | 
        
         680 mm *3  | 
        
         920 mm *3  | 
        
         1160 mm *3  | 
        
         1400 mm *3  | 
    |||
| 
         Total length  | 
        
         350 mm  | 
        
         560 mm  | 
        
         800 mm  | 
        
         1040 mm  | 
        
         1280 mm  | 
    |||
| 
         No. of electrodes  | 
        
         5  | 
        
         9  | 
        
         13  | 
        
         17  | 
        
         21  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 to 36 VDC ±10%  | 
    ||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V) or 500 mA (at 36 V)  | 
    |||||||
| 
         Overvoltage category  | 
        
         I  | 
    |||||||
| 
         Pollution degree  | 
        
         2  | 
    |||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    ||||||
| 
         Relative humidity  | 
        
         35 to 85%RH (no condensation)  | 
    |||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    ||||||
| 
         Body  | 
        
         ABS / PBT / PP / LCP / PPS / SPS / SUS  | 
    |||||||
| 
         Weight  | 
        
         670 g  | 
        
         850 g  | 
        
         1070 g  | 
        
         1270 g  | 
        
         1500 g  | 
    |||
| 
         *1 Values were measured under the following conditions.  | 
    ||||||||
Network model
| 
         Model  | 
        
         SJ-E156N  | 
        
         SJ-E180N  | 
        
         SJ-E204N  | 
        
         SJ-E228N  | 
        
         SJ-E252N  | 
        
         SJ-E300N  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Ion generation method  | 
        
         Corona discharge method  | 
    ||||||||
| 
         Structure  | 
        
         Shockless resistor connection type  | 
    ||||||||
| 
         Voltage application method/  | 
        
         Pulse AC method/±8,000 V  | 
    ||||||||
| 
         Ion balance control method  | 
        
         Hi-Power I.C.C. method  | 
    ||||||||
| 
         Ion balance  | 
        
         ±30 V *1  | 
    ||||||||
| 
         Operating distance  | 
        
         50 to 2,000 mm  | 
    ||||||||
| 
         Communication feature  | 
        
         RS-485 communication/remote control communication  | 
    ||||||||
| 
         Major features  | 
        
         Condition alarm, ion level alarm, and alarm output  | 
    ||||||||
| 
         Air connection port  | 
        
         Rc 1/8  | 
    ||||||||
| 
         Air supply pressure  | 
        
         0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa) *2  | 
    ||||||||
| 
         Effective length  | 
        
         1640 mm *3  | 
        
         1880 mm *3  | 
        
         2120 mm *3  | 
        
         2360 mm *3  | 
        
         2600 mm *3  | 
        
         3080 mm *3  | 
    |||
| 
         Total length  | 
        
         1520 mm  | 
        
         1760 mm  | 
        
         2000 mm  | 
        
         2240 mm  | 
        
         2480 mm  | 
        
         2960 mm  | 
    |||
| 
         No. of electrodes  | 
        
         25  | 
        
         29  | 
        
         33  | 
        
         37  | 
        
         41  | 
        
         49  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 to 36 VDC ±10%  | 
    |||||||
| 
         Current consumption  | 
        
         700 mA (at 24 V) or 500 mA (at 36 V)  | 
    ||||||||
| 
         Overvoltage category  | 
        
         I  | 
    ||||||||
| 
         Pollution degree  | 
        
         2  | 
    ||||||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C  | 
    |||||||
| 
         Relative humidity  | 
        
         35 to 85%RH (no condensation)  | 
    ||||||||
| 
         Material  | 
        
         Electrode probe  | 
        
         Tungsten  | 
    |||||||
| 
         Body  | 
        
         ABS / PBT / PP / LCP / PPS / SPS / SUS  | 
    ||||||||
| 
         Weight  | 
        
         1700 g  | 
        
         1900 g  | 
        
         2100 g  | 
        
         2300 g  | 
        
         2500 g  | 
        
         2900 g  | 
    |||
| 
         *1 Values were measured under the following conditions.  | 
    |||||||||